Skip to content
NJ · PA · PHILA · DE
Steele Services — Fire Protection Specialists

Heat checked · Drains emptied · Antifreeze tested

Fire Sprinkler Winterization

Fire sprinkler winterization for commercial buildings across New Jersey, Pennsylvania and Delaware. One visit gets your sprinkler system ready for the cold, and leaves your staff a simple checklist for the rest of the winter.

We check the heat in the rooms that hold your sprinkler valves, empty the water that collects at the low points of dry systems, test any antifreeze, and look over the spaces where sprinkler pipe runs close to the cold. You get a written report and a price for anything that needs fixing, before any work starts.

From $250 for one building with one fire sprinkler system. Added systems, antifreeze replacement and repairs are priced on top.

Sprinkler riser valve with its trim piping and two pressure gauges
Sprinkler riser · valve and gauges
Price
From $250 for one building, one fire sprinkler system
When
In the fall, before the first hard freeze. Mid-winter visits too.
Systems
Wet, dry, preaction and antifreeze sprinkler systems
Temperature
Sprinkler pipe that holds water, not antifreeze, is kept at 40°F or warmer
You get
A written report, a price for any fixes, and a checklist for your staff
Coverage
NJ · PA · PHILA · DE

The visit

What the fire sprinkler winterization visit includes.

In one visit, we will walk through your entire system, and present a written report of our findings.

01

The winter visit

Before the cold comes, let us help you protect the parts of your sprinkler system that matter most in winter.

  • Heat checked in the rooms that hold your dry and preaction valves, your riser and your fire pump
  • Low-point drains on dry and preaction systems emptied, and each one's location recorded
  • Air pressure and the air compressor checked on dry and preaction systems
  • Antifreeze sampled at the top and bottom of each antifreeze system, and checked against the coldest temperatures in your area
  • Cold-weather alarms tested, with the signal confirmed at your alarm panel
  • The small automatic drain on the fire department connection checked
  • Enclosures and heaters on the backflow preventer for your sprinkler water supply looked over
  • A walk-through of the spaces where sprinkler pipe runs close to the cold

After the visit

Any repair work is quoted and approved first.

02

When something is found

We will provide a written quote for any repairs that we find.

  • Leaking or cracked low-point drains repaired
  • Antifreeze replaced with an approved, factory-mixed solution
  • Air compressor maintenance and repair
  • Fire department connection and backflow preventer repairs, including freeze damage
  • A plan for spaces that stay cold, from insulation to moving that section onto a dry system
  • Everything priced and approved before we start
03

Through the rest of the winter

We will help you get ready for the winter by getting your staff prepared.

  • A written checklist for your staff, left with them on the visit: which rooms to check for heat, and who to call
  • A short handover on site during the visit, so your staff know which rooms to check and what to keep an eye on
  • Mid-winter follow-up visits, if you want them, priced separately
  • Emergency repair around the clock, priced separately

How it works

Don't take unnecessary risks. Our simple review can help prevent larger problems.

  1. 01

    Scheduling before the first freeze

    If we already inspect your building, we have your systems on file. If not, tell us your buildings and which sprinkler systems are in them. We'll set a date in the fall, before the first hard freeze. Even if it is already winter, we can still come out and perform our review.

  2. 02

    The visit

    A technician works through the checklist on each system, then shows your staff which rooms to check and what to keep an eye on.

  3. 03

    The report

    You get a written report of what we checked and what we found, with a price for anything that needs fixing. Nothing is repaired without your go-ahead.

  4. 04

    Next fall

    We'll contact you next fall to book the visit again.

Common winter findings

What we find most often in winter.

These come up in our own inspection record. Each one can be planned for once it's found.

01

Water left at the low points of a dry system

A dry system's pipe is meant to hold air, but water can still collect in it, from moisture in the compressed air and from testing. It settles at the low points, where small drains let it out. Emptying them before the cold is one of the simplest parts of the visit, and one of the most useful.

NFPA 25 (2017) §13.4.5.3.2

02

A valve room colder than the rest of the building

The room that holds a dry or preaction valve is kept at 40°F or warmer, with heat that is built in. Heaters wear out and thermostats drift, and a corner by an outside wall can sit well below the rest of the room. A temperature check at the valve finds it.

NFPA 25 (2017) §4.1.2 · NJ Fire Code (2018) §901.4.6.3

03

Antifreeze that has changed since it was installed

The antifreeze in a sprinkler system can change over the years. We sample it at the top and bottom of the system and check that it still protects to the coldest temperature in your area. Where it doesn't, or its type can't be identified, it's replaced with an approved, factory-mixed solution.

NFPA 25 (2017) §5.3.3

04

Sprinkler pipe close to the cold

Sprinkler pipe often runs where the heat doesn't reach: over loading dock doors, in stairwells and attics, and in entry vestibules. Finding those spots before the cold means the fix can be planned, from insulation to moving that section onto a dry system.

NFPA 13 (2016) §8.16.4.1.1

05

A cold-weather alarm that reaches your monitoring company

Where a valve room has a low-temperature alarm, on the winter visit we test it and confirm the signal reaches your alarm panel and your monitoring company.

NFPA 25 (2017) §13.4.5.2.7

Common Questions

Fire sprinkler winterization — questions we get asked.

Ask Us Directly

What does fire sprinkler winterization include?

One visit before the cold. We check the heat where your sprinkler valves are, empty the low-point drains on dry systems, test any antifreeze and cold-weather alarms, check the fire department connection's drain, and look over the spaces where pipe runs close to the cold. You get a written report, a price for any fixes, and a checklist for your staff.

When should I book it?

In the fall, before the first hard freeze. Even if it is already winter, we can still come out and perform our review.

How much does it cost?

The winter visit starts at $250 for one building with one fire sprinkler system, whether it is wet, dry, preaction or antifreeze. Each added system adds to the price, and so does replacing antifreeze. Repairs are quoted separately, and you approve any price before work starts.

Is winterization part of my inspection contract?

It's a separate visit, at the same price for every customer. Some winter items overlap with a fall inspection, so if you're already on a schedule with us, we'll tell you which ones before you book.

What should I do if a fire sprinkler pipe freezes or breaks?

Call our 24/7 line at 1-888-306-8430 and tell us where the water is coming from. Whether any part of the system should be shut off while the repair is arranged is a decision to make with us when you call.

Tell us your systems. We'll get them ready for winter.

One conversation books the visit. We'll confirm the price and find a date that works for you.