Emergency & Exit Lighting

We test emergency lights and exit signs across every floor, suite and stairwell — monthly functional checks and the annual ninety-minute discharge test.

Monthly functional tests, the annual ninety-minute discharge test, battery replacement and unit repair — across every floor, suite and stairwell. Tested on the Life Safety Code schedule and documented.

Combination exit sign and emergency light unit mounted above a doorway
Combination exit sign · emergency light heads
Standard
NFPA 101 — Life Safety Code
Monthly
30-second functional test, every unit
Annually
90-minute full-duration discharge test
Scope
Emergency lights, exit signs and combo units
Reporting
Unit-by-unit results with locations
Coverage
NJ · PA · DE — statewide

Core services

Inspection and testing, installation, maintenance.

We keep the full service history on file, so when we need to visit for maintenance we already know your system.

01

Inspection & Testing

The monthly and annual tests the Life Safety Code requires, on every unit in the building — not a sample.

  • Monthly 30-second functional test on every emergency light and exit sign
  • Annual 90-minute discharge test proving the battery carries full duration
  • AC power confirmed at each unit, not just at the panel
  • Illumination checked along the actual egress path
  • Failed units identified by floor, suite and location
  • Written record retained for the fire official
02

Installation

New units, replacements for obsolete fixtures, and coverage where the egress path has changed.

  • Emergency light and exit sign installation for new construction and fit-out
  • Replacement of units past service life or discontinued by the manufacturer
  • Added coverage when walls, suites or egress routes change
  • Combo unit replacement where separate fixtures no longer make sense
  • Correction of units installed without a code-compliant power source
03

Maintenance & Repair

Battery replacement, unit repair and the follow-up that closes out a known issue.

  • Battery replacement on units that fail the discharge test
  • Repair or replacement of units with no AC power at the fixture
  • Lamp and LED head replacement
  • Re-test and record update after every repair
  • Deficiency repair priced and approved before we start

Service frequencies

Find the service frequencies your system requires.

The monthly 30-second test is something in-house maintenance staff can carry — we will set up the log sheet and show them how. The annual 90-minute discharge test and the written record need a certified technician.

NFPA 101

Emergency & Exit Lighting

5Intervals

No.FrequencyRequired activityReference
01MonthlyFunctional test of every unit — 30 seconds minimum§7.9.3.1
02MonthlyExit signs — illumination confirmed on every unit§7.10.9
03AnnuallyFull-duration discharge test — 90 minutes on battery§7.9.3.1
04AnnuallyBatteries load-tested and replaced where they fail§7.9.3
05OngoingWritten record of every test retained for the AHJ§7.9.3.1.3

Intervals shown are the NFPA baseline. Your local fire official or insurance carrier may require more. Read the standards free at NFPA.org (opens in a new tab)

Contact Us to Schedule Service

Common deficiencies

What actually fails inspection.

Emergency lighting fails quietly — there is no panel to report a dead unit. These are some of the most common findings we come in contact with.

Inherited a system?

We onboard systems installed by other contractors. First visit is an inventory and a condition report — priced, itemized, no surprises.

Contact Us
01

Batteries that no longer hold ninety minutes

A unit can light up when you press the test button and still fail the annual discharge test twenty minutes in. Thirty seconds shows the lamp works. Ninety minutes shows whether the battery does.

NFPA 101 §7.9.3.1

02

No AC power at the fixture

Units get disconnected during a lighting retrofit, a ceiling change or a tenant fit-out. A dead unit looks exactly like a working one, so we check power at each fixture rather than at the panel.

NFPA 101 §7.9.2

03

Exit signs that do not light

Failed exit signs are the single most common finding in this category, and they cluster — when one is out on a floor, several usually are. They are inexpensive to fix and conspicuous to an inspector walking the egress path.

NFPA 101 §7.10

04

Units past their replace-by date

We regularly find fixtures with a replace-by date years in the past still mounted on the wall. Once a unit is past service life the battery is the part that goes first, and there is no indicator to tell your staff it happened.

NFPA 101 §7.9.3

Common Questions

Emergency & Exit Lighting — questions we get asked.

Ask Us Directly
How often do emergency lights and exit signs need to be tested?

A 30-second functional test monthly and a 90-minute full-duration discharge test annually per code, with a written record retained for the fire official.

What is the 90-minute test and why does it matter?

It runs each unit on battery for the full 90 minutes the code requires. A unit can light up for 30 seconds and still die twenty minutes into the annual test — the monthly test proves the lamp works, the annual test proves the battery does.

Why do exit signs fail so often?

They fail silently. Nothing on a panel reports a dead exit sign, so a building can go years believing it is covered. Units also get disconnected during lighting retrofits and tenant fit-outs — the fixture is still on the wall, just unpowered.

Can our own maintenance staff do the monthly test?

Yes, and it is a sensible thing to keep in house. We will set up the log sheet and show them what to record. The annual 90-minute test and the written record need a certified technician.

We work on what's already in your riser room

LithoniaDual-LiteExitronixHubbellSure-LitesCooper

No rip-and-replace pitch on the first visit. We hold current manuals and parts references for every line above — when a system genuinely can't be maintained any longer, we'll show you why before we quote a replacement.

Emergency & Exit Lighting in trouble right now?

Call 1-888-306-8430 — the line is answered around the clock by a technician who can access your system information and start guidance on the phone.